Combined Clinical Chemistry and Coagulation Multitest Analyzer Touch Screen BAS-150 TS PLUS
$89.00
Combined Clinical Chemistry and Coagulation Multitest Analyzer Touch Screen BAS-150 TS PLUS is a TOUCH SCREEN Microprocessor Biochemical and Coagulation Analyzer, which measures the biological indicators, more than 50 elements plus Coagulation test TT, PT, APTT.
The BAS-150 TS Plus is open to being used with all brands of biochemistry reagents.
THIS BIOCHEMISTRY ANALYZER CAN TEST SAMPLES IN TWO WAYS,
BY SUCTION PUMP AND BY DISPOSABLE CUVETTE
Features:
- Latest concept and technology
- Flow through cell, micro and macro cuvette available
- Lower energy consuming technique
- Color touch screen
- Multi-language, and more
- Coagulation Testing
- 7.0″ True Color Touch Screen (800 x 480 pixels)
- Inside multi-function incubator
- Universal power supply
- Enzyme Kinetic GPT GOT tests
- Sample blood serum
- Volume: Reagent plus sample serum 500 ul
- Reagent will give ratio
- The suction volume is 500 ul
- Halogen lifetime is 1500 hours
- Calibration is leaner
- Photometric resolution is 0.0002A
Function: | Chemistry + Coagulation |
Analysis method: |
Photometry: End point, fixed time, kinetic, serum blank, Bi-chromatic, double-reagent, multi-point |
Wavelength: | Chemistry: 340, 405, 492, 510, 546, 620, 670nm. Other available on request. Coagulation: 450, 670nm. Others on request. |
Cuvette: | Flow through cell, direct reading, and coagulation cuvette available |
Sample Volume: | 50-500 ul |
Incubator: | 2 reagent and 20 sample incubation positions, controlled at 37±0.1°C |
Temp. for cuvette | 37±0.1°C |
Drift | ≤0.0001 OD/hr |
Quality Control: | Quality control for normal and abnormal value, automatic statistics, and analysis of control data |
Display: | 7 inch, color touch screen |
Storage: | 1,000 test results |
Printer: | Built-in thermal printer |
Interface: |
USB & RS-232 |
Languages: | English, Spanish, French, Russian, Portuguese, Chinese, Others available on request. |
Power: | 110V/60Hz, or 220V/50Hz 150W |
Dimensions: | 340mm x 380mm x 210mm |
Weight: | 6.5 kg |
Test Menu: | Chemistry: Kidney function, liver function, cardiac markers, minerals, blood disorders, blood lipids, drug of abuse, miscellaneous, etc. Coagulation: PT, APTT, FBG, TT, D-Dimer, FDP, AT-III, PC, PS, VWF, Factor V, VII, VIII, IX, X, XI, XII, deficient substrate, etc. |
Brand | |
---|---|
Height | 79.5 cm |
Length | 46.5 cm |
Related products
DW-20 De-Ionized Water Distiller with Gauge
Water Processing Volume: | 20L/hour |
Installation requires: | |
a) Water Conductivity: | <400us/cm |
b) Water Pressure: | 0.1-0.4 Mpa (if no need extra pump) |
c) Water Temperature: | 5°C-45°C |
Water Speed of Output: | 1.5-2L/min |
After Purification Conductivity: | >16 Ion< 0.1ppb |
Power: | 50W |
Dimensions: | 420mm x 350mm x 500mm |
Weight: | 25-30 kg |
Clinical Microplate Reader EMR-500 Touch Screen
Clinical Microplate Reader EMR-500 Touch Screen has eight channel photometers for the sequential and simultaneous for the sequential and simultaneous reading of microplates. Providing the best level of sensitivity for variable assay conditions, with powerful software are able to perform reading and data procession with relative memorization.
Features:
One of the important advantages of this instrument is that it is open to working with any proper reagent and with many applications.
- Eight channel photometers for the sequential and simultaneous for the reading of microplates.
- Providing the best level of sensitivity for variable assay conditions, with powerful software are able to perform reading and data procession with relative memorization.
- Ability to read flat, U and V bottom.
- Auto calibration before each reading.
- Programmable variable speed shaking.
- Measurement range: 0.000-3.500A
- Light Source: Halogen
- EMR-500 can work by itself, and can connect to the computer. Can use with Windows XP and Windows 7.
|
Analyzer BAS-100 TS
The BAS-100 TS is open to being used with all brands of biochemistry reagents.
Single chip machine, WindowsCE operating system, does not require Windows XP or Windows 7.
Optics: 7 filters, 340, 405, 450, 505, 546, 578, 630. Thermostatic Control: Flow Cell Temperature: 37C Peltier Elements. Flow through cell: 32ul Suction Pump System Display:7.0 inch TFT Color touch screen Precision: +-0.2C Continuous Memory: 200 assay program,200000 results Printer: Built-in thermal printer, 57mm. wide paper Power Supply: AC85-260; 50Hz or 60Hz Sample blood serum Volume: Reagent plus sample serum 500 ul Reagent will give ratio The suction volume is 500 ul Halogen lifetime is 1500 hours Calibration is leaner Photometric resolution is 0.0002A
- Photometric scanning of Spectrum, Analysis in multiple longitude of wave and kinetics, endpoint, fixed time, kinetic. Blank of water or blank of reagent method can be linear or nonlinear, according to the type of reagent you are using.
- Diagnosis of Operation
- Automatic Calibration
- System of aspiration of sample (Pale of flow, Aspiration System, Faslk of Residuals, Tubes, Connectors, Etc)
- Power Cable Included
- Works with WindowsCE operating system. Single chip machine, does not require Windows XP or Windows 7.
- Enzyme Kinetic GPT GOT tests.
Clinical Biochemistry Touch Screen Analyzer with Temperature Control and Internal Printer BAS-120TS
Clinical Biochemistry Touch Screen Analyzer with Temperature Control and Internal Printer BAS-120TS is a TOUCH SCREEN Microprocessor Biochemical Analyzer, which measures over 50 biological indicators.
The BAS-120TS is open to being used with all brands of biochemistry reagents.
THIS BIOCHEMISTRY ANALYZER CAN TEST SAMPLES IN TWO WAYS, BY SUCTION PUMP AND BY DISPOSABLE CUVETTE
Features:
- Powerful Software
- 7.0" Touch Screen
- Multi-language
- Built-in Printer
- USB port for external printer, online operation, keyboard,software update (optional)
- Very easy to use, user-friendly interface
- 50 Biochemistry tests
- Sample blood serum
- Volume: Reagent plus sample serum 500 ul
- Reagent will give ratio
- The suction volume is 500 ul
- Halogen lifetime is 1500 hours
- Calibration is leaner
- Photometric resolution is 0.0002A
Reading Cuvette | Both flow through cell and direct reading cuvette |
Measuring Volume | 500ul |
Incubator | 20 incubating positions |
Photometric System | Light source: 6V/10W halogen lamp Wavelength: 340/405/492/510/546/578/620nm , 2 more filters upon request Wavelength accuracy: ±2nm |
Thermostatic Control | Temperature: 25 °C,30 °C, 37 °C Precision: ±0 °C |
Measuring System | Method: End point, Fixed time,Multistandards,Differential, Bichromatic, Immunoturbidimetric,etc. Measuring Range: 0-3.000 O.D Photometric Linearity: ± 2% (0-3.000 O.D) Photometric Accuracy: ±1% (0-3.000 O.D) Carry-over: ≤1% |
Drift | <0.005 0.D/hr |
Test Menu | Chemistry: T.B LI r-GT/GGT CHO Ca APOB-1/B CHE D.B LI ALP/AKP TG CL APOB CREA TP UREA CK P CK-MB Mg ALB LOH C ASO AFU Lactic Acid ALT/GPT UA a-HBDH C02 FMN LP(a) AST/GOT GLU AMY LDL-C HDL-C |
Quality Control | Excellent Q.C function, Q.C chart may be displayed and printed |
Display | 7 inch touch screen |
Storage | Over 200 programs, 1000 test results |
Printer | Built-in thermal printer |
LIS Software | Optional |
Interface | USB port for external printer, keyboard,software update (optional) |
Power Supply | AC 110V/60Hz or 220V/50 Hz |
Dimensions | 34cm x 38cmx 18cm |
Weight | 8.0Kg |
Reviews