Analyzer BAS-100 TS
Optics: 7 filters, 340, 405, 450, 505, 546, 578, 630. Thermostatic Control: Flow Cell Temperature: 37C Peltier Elements. Flow through cell: 32ul Suction Pump System Display:7.0 inch TFT Color touch screen Precision: +-0.2C Continuous Memory: 200 assay program,200000 results Printer: Built-in thermal printer, 57mm. wide paper Power Supply: AC85-260; 50Hz or 60Hz Sample blood serum Volume: Reagent plus sample serum 500 ul Reagent will give ratio The suction volume is 500 ul Halogen lifetime is 1500 hours Calibration is leaner Photometric resolution is 0.0002A
Photometric scanning of Spectrum, Analysis in multiple longitude of wave and kinetics, endpoint, fixed time, kinetic. Blank of water or blank of reagent method can be linear or nonlinear, according to the type of reagent you are using. Diagnosis of Operation Automatic Calibration System of aspiration of sample (Pale of flow, Aspiration System, Faslk of Residuals, Tubes, Connectors, Etc) Power Cable Included Works with WindowsCE operating system. Single chip machine, does not require Windows XP or Windows 7. Enzyme Kinetic GPT GOT tests. Details:: Assay method:- Absorbance, concentration, factor, 1 point end point, 2 point end (Sample blank), fixed time, kinetic, and dichromatic, immunoturbidimetric. Coagulation (optional).
- 7 filters, 340, 405, 450, 505, 546, 578, 630 as standard configuration. (5 years warranty for each filter)
- 6V 10W Long-life Tungsten halogen lamp. Service life 2000 hours. Light has auto shutdown function that will extend usage period. Auto-Sleep function.
- 0 inch TFT Color touch screen,260000 Pixel,800x480 resolution; real time to show response curve
- Built-in Thermal Printer, 57mm printer paper. Paper alarm, transparent cover; easy installation
- 37℃ and room temperature are standby; temperature accuracy±1℃, by means of Peltier elements
- 32ul, 10mm
- Abs
- 0 – 3.5 Abs
- 0000-2.5000(10mm flowcell)
- 0000-3.5000(6mm flowcell)
- < 8 nm
- 200 – 5000 ul at least
- <1%;
- <0.005Abs/hour
- 0001Abs;
- <0.005Abs/hour
- CV≤1%
- L-J QC chart , Westguard Multi-regulation analysis.
- Window CE 6.0 operation system,high-capacity storage; edit 200 assay program,200000 results. Unlimited storage by connecting to computer. Single chip machine, does not require Windows XP or Windows 7.
- Available in 4 different languages
- ARM Cortex-A8, 720MHz
- DDR2 SDRAM: 1G bit
- Flash: 256 MB
- Over 200 programs, 200,000 results can be stored
- USB Mouse; USB keypad; USB Printer; 4 USB ports for Keyboard, Mouse, Printer, U Disk, Bar Code Reader. 1 USB Slave for PC connections (supports PC software control function). 1 Ethernet port. Supports all HP series inkjet printers; Computer control software,LIS system available. External scanner is available. Support remote diagnostics.
- Temperature: 10℃~37℃.Humidity: ≤85%.
- Wide power supply: 100-240V 50Hz or 60Hz.
- 400mm (L) x 300mm (W) 160mm (H)
- 17 lbs
Clinical Biochemistry Touch Screen Analyzer with Temperature Control and Internal Printer BAS-120TS
Clinical Biochemistry Touch Screen Analyzer with Temperature Control and Internal Printer BAS-120TS is a TOUCH SCREEN Microprocessor Biochemical Analyzer, which measures over 50 biological indicators.
The BAS-120TS is open to being used with all brands of biochemistry reagents.
THIS BIOCHEMISTRY ANALYZER CAN TEST SAMPLES IN TWO WAYS, BY SUCTION PUMP AND BY DISPOSABLE CUVETTE
Features:
- Powerful Software
- 7.0" Touch Screen
- Multi-language
- Built-in Printer
- USB port for external printer, online operation, keyboard,software update (optional)
- Very easy to use, user-friendly interface
- 50 Biochemistry tests
- Sample blood serum
- Volume: Reagent plus sample serum 500 ul
- Reagent will give ratio
- The suction volume is 500 ul
- Halogen lifetime is 1500 hours
- Calibration is leaner
- Photometric resolution is 0.0002A
- Both flow through cell and direct reading cuvette
- 500ul
- 20 incubating positions
- Light source: 6V/10W halogen lamp
- Wavelength: 340/405/492/510/546/578/620nm , 2 more filters upon request
- Wavelength accuracy: ±2nm
- Temperature: 25 °C,30 °C, 37 °C
- Precision: ±0 °C
- Method: End point, Fixed time,Multistandards,Differential, Bichromatic, Immunoturbidimetric,etc.
- Measuring Range: 0-3.000 O.D
- Photometric Linearity: ± 2% (0-3.000 O.D)
- Photometric Accuracy: ±1% (0-3.000 O.D)
- Carry-over: ≤1%
- <0.005 0.D/hr
- Chemistry: T.B LI r-GT/GGT CHO Ca APOB-1/B CHE D.B LI ALP/AKP TG CL APOB CREA TP UREA CK P CK-MB Mg ALB LOH C ASO AFU Lactic Acid ALT/GPT UA a-HBDH C02 FMN LP(a) AST/GOT GLU AMY LDL-C HDL-C
- Excellent Q.C function, Q.C chart may be displayed and printed
- 7 inch touch screen
- 200 programs, 1000 test results
- Built-in thermal printer
- Optional
- USB port for external printer, keyboard,software update (optional)
- AC 110V/60Hz or 220V/50 Hz
- 34cm x 38cmx 18cm
- 8.0Kg
Clinical Microplate Reader EMR-500 Touch Screen
Clinical Microplate Reader EMR-500 Touch Screen has eight channel photometers for the sequential and simultaneous for the sequential and simultaneous reading of microplates. Providing the best level of sensitivity for variable assay conditions, with powerful software are able to perform reading and data procession with relative memorization.
Features:
One of the important advantages of this instrument is that it is open to working with any proper reagent and with many applications.
- Eight channel photometers for the sequential and simultaneous for the reading of microplates.
- Providing the best level of sensitivity for variable assay conditions, with powerful software are able to perform reading and data procession with relative memorization.
- Ability to read flat, U and V bottom.
- Auto calibration before each reading.
- Programmable variable speed shaking.
- Measurement range: 0.000-3.500A
- Light Source: Halogen
- EMR-500 can work by itself, and can connect to the computer. Can use with Windows XP and Windows 7.
- 8 channels, 96 well plate
- Cut-off, single and multi-standard, O.D. bichromatic, dynamic reading, etc.
- 6 seconds (fast kinetic measurements)
- 001-3.500Abs
- ±1% or ±0.001A
- <1.0%
- <0.005Abs/hr
- <±1.0%
- <±0.001A
- <±0.002A
- 405/450/492/630nm
- Automatic focusing function makes the results more precise
- Yes
- 100 programs
- Touch screen
- RS-232 and USB port
- Internal printer (External printers are available on request)
- AC 220V 50Hz or 110V 60 Hz
- 46cm*33cm*18cm
- 5kg
Combined Clinical Chemistry and Coagulation Multitest Analyzer Touch Screen BAS-150 TS PLUS
THIS BIOCHEMISTRY ANALYZER CAN TEST SAMPLES IN TWO WAYS, BY SUCTION PUMP AND BY DISPOSABLE CUVETTE
Features:- Latest concept and technology
- Flow through cell, micro and macro cuvette available
- Lower energy consuming technique
- Color touch screen
- Multi-language, and more
- Coagulation Testing
- 7.0" True Color Touch Screen (800 x 480 pixels)
- Inside multi-function incubator
- Universal power supply
- Enzyme Kinetic GPT GOT tests
- Sample blood serum
- Volume: Reagent plus sample serum 500 ul
- Reagent will give ratio
- The suction volume is 500 ul
- Halogen lifetime is 1500 hours
- Calibration is leaner
- Photometric resolution is 0.0002A
- Chemistry + Coagulation
- Photometry: End point, fixed time, kinetic, serum blank, Bi-chromatic, double-reagent, multi-point
- Coagulation: Nephelometry
- Chemistry: 340, 405, 492, 510, 546, 620, 670nm. Other available on request.
- 450, 670nm. Others on request.
- Flow through cell, direct reading, and coagulation cuvette available
- 50-500 ul
- 2 reagent and 20 sample incubation positions, controlled at 37±0.1°C
- 37±0.1°C
- ≤0.0001 OD/hr
- Quality control for normal and abnormal value, automatic statistics, and analysis of control data
- 7 inch, color touch screen
- 1,000 test results
- Built-in thermal printer
- USB & RS-232
- English, Spanish, French, Russian, Portuguese, Chinese, Others available on request.
- 110V/60Hz, or 220V/50Hz 150W
- 340mm x 380mm x 210mm
- 5 kg
- Chemistry: Kidney function, liver function, cardiac markers, minerals, blood disorders, blood lipids, drug of abuse, miscellaneous, etc.
- PT, APTT, FBG, TT, D-Dimer, FDP, AT-III, PC, PS, VWF, Factor V, VII, VIII, IX, X, XI, XII, deficient substrate, etc.
DW-20 De-Ionized Water Distiller with Gauge
Water Processing Volume: | 20L/hour |
Installation requires: | |
a) Water Conductivity: | <400us/cm |
b) Water Pressure: | 0.1-0.4 Mpa (if no need extra pump) |
c) Water Temperature: | 5°C-45°C |
Water Speed of Output: | 1.5-2L/min |
After Purification Conductivity: | >16 Ion< 0.1ppb |
Power: | 50W |
Dimensions: | 420mm x 350mm x 500mm |
Weight: | 25-30 kg |